EasyManua.ls Logo

Midea DLFSHBH12XAK - Index; Indoor or Outdoor DC Fan Motor; Voltage

Midea DLFSHBH12XAK
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
:
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
29
Index
1. Indoor or Outdoor DC Fan Motor (control chip is in fan motor)
Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in the fan motor connector. If the voltage value is
not in the range shown in Table 17 and 18, the PCB is faulty and needs to be replaced.
• DC motor voltage input and output (voltage: 220-240V~):
Table 17 — Voltage
•DC motor voltage input and output (voltage: 115V~):
Table 18 — Voltage
Table 19 — Indoor DC Fan Motor
No. Color Signal Voltage
1 Red Vs/Vm 192V~380V
2 --- --- ---
3 Black GND 0V
4 White Vcc 13.5-16.5V
5 Yell ow Vsp 0~6.5V
6 Blue FG 13.5V-16.5V
No. Color Signal Voltage
1 Red Vs/Vm 140V~190V
2 --- --- ---
3 Black GND 0V
4 White Vcc 13.5-16.5V
5 Yell ow Vsp 0~6.5V
6 Blue FG 13.5V-16.5V

Table of Contents

Related product manuals