GD Midea Refrigerant Equipment Co. Ltd                                 Service manual for Electrolux split Series 
10 
adjacent diagram. 
 
2.4.2.1.8 Wrap the insulation material around the 
connecting portion. 
 
●  Overlap the connection pipe heat insulation 
and the indoor unit pipe heat insulation material. 
Bind them together with vinyl tape so that there is 
no gap. 
 
●  Wrap the area which accommodates the rear 
piping housing section with vinyl tape. 
 
● Bundle the piping and drain hose together by 
wrapping them with vinyl tape over the range 
within which they fit into the rear piping housing 
section. 
 
 
 
2.4.2.2 For rear left piping 
Note: When viewed from the front of the indoor 
unit. 
 
 
2.4.2.2.1 Route the indoor tubing and the drain 
hose to the required piping hole position in the 
direction of left. 
2.4.2.2.2 Insert the connecting cable into the 
indoor unit from the outdoor unit through the 
piping hole. 
●  Do not connect the cable to the indoor unit. 
●  Make a small loop with the cable for easy   
connection later. 
2.4.2.2.3 Tape the drain hose and the connecting 
cable. Be sure that the drain hose is located at the 
lowest side of the bundle. Locating at the upper 
side can cause drain    pan to overflow inside the 
unit. 
 
Note: If the drain hose is routed inside the room,   
insulate the hose with an insulation material so 
that dripping from "sweating" (condensation) will 
not damage furniture or floors. 
*Foamed polyethylene or equivalent is 
recommended. 
2.4.2.2.4 Insert the piping, drain hose and the 
connecting cable into the piping hole. 
 
2.4.2.2.5 Indoor unit installation 
●  Hang the indoor unit from the hooks at the top 
of the installation plate. 
●  Insert a spacer between the indoor unit and 
the installation plate to separate the bottom of the 
indoor unit from the wall. 
 
2.4.2.2.6 Connecting the piping to the indoor unit 
and the drain hose to drain pipe. 
●  Align the centre of the piping and sufficiently 
tighten the flare nut by hand.