Service Manual_2020-V1.0
43
enter into
forced cooling
mode
button for the second time
LED indicators light off, then the compressor and
the fan will start working
In forced cooling mode, if no
button is pressed within 36 hours,
then the refrigerator will exit the test mode and
return to normal operation mode
Select to
enter into
forced
compensating
heating mode
Enter into test mode and press
button for the first time
LED indicators on Gear 3, 4 light up and other
LED indicators light off, then the compensating
heater will start working
then the refrigerator will exit the test mode and
return to normal operation mode
Select to
enter into
forced
defrosting
mode
Enter into test mode and press
button for the third time
LED indicators on Gear 1, 4 light up and other
LED indicators light on, then the compressor and
the fan will stop working, The heater open,
refrigerator into forced frost
In forced defrosting mode, when
the defrosting sensor reach a
temperature of 8°C and the
defrosting heater has been
working for 2 minutes,
then the refrigerator will exit the test mode and
return to normal operation mode
In forced defrosting mode, if the
temperature of defrosting sensor is
always lower than 8°C and the
defrosting heater has been
working for 1 hour,
then the refrigerator will exit the test mode and
return to normal operation mode
Select to exit
the test mode
Enter into test mode and press
button for the third time
then the refrigerator will exit the test mode and
return to normal operation mode