Press" ▲ " or " ▼ " to select "CLEAR RUN TIME" and press " " to confirm. Display as
follows:
SELECT ADDRESS
CLEAR COMP TIME?
07
OK
NO
CLEAR FIX PUMP TIME?
CLEAR INV PUMP TIME?
NO
NO
Press " ▲ " or " ▼ " to select "SELECT ADDRESS", press " ◄ " or " ► " to select address
value.
Press " ▲ " or " ▼ " to select clear or not, and press " ◄ " or " ► " to select YES or NO, and
press " " to confirm.
Setting address :
Press " ▲ " or " ▼ " under "SERVICE MENU" page to select "SETTING ADDRESS" (Can
also enter by combining buttons pressing " ", " ► " for 3s). Press " " and enter
submenu.
SERVICE MENU
OK
STATE QUERY
SETTING ADDRESS
HEAT CONTROL
CLEAR HISTORY ERROR
1/3
SETTING ADDRESS
CONTROLLER
ADDRESS
CONTROL ENABEL
10
OK
MODBUS ENABLE
MODBUS ADDRESS
NO
NO
#
10
#
Press " ▲ " or " ▼ " to select item and press " ◄ " or " ► " to set value. Then press " "
to confirm and " " to back.
◆
Heat control
HEAT1 means pipe electric heating in cooling/heating mode. HEAT2 means tank electric
heating in DHW mode.
Press " ▲ " or " ▼ " to select "HEAT CONTROL" under "SERVICE MENU" page. Press
" " and enter submenu.