EasyManua.ls Logo

Midea KJRM-120H2/BMWKO-E - Page 35

Midea KJRM-120H2/BMWKO-E
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
Press " " or " " to select item to be set and press " " or " " to set value. Press
" " to confirm. Back to homepage if there is no operation within 60s. Detailed setup
information:
Parameter Setting range
T_DIFF_PRO 8
15°C
T_DIFF_PRO 1
5°C
Defrosting Setting:
Select "SET DEFROSTING" and press " " to entry. Display as follows:
SET DEFROSTING
T_FROST
35 min
OK
C
T_DEFROST_IN
T_FROST_OUT
C
Press " " or " " to select item to be set and press " " or " " to set value. Press
" " to confirm. Back to homepage if there is no operation within 60s.
Detailed setup information:
Parameter Setting range
T_FROST 20
120min
T_DEFROST_IN -5
5°C
T_FROST_OUT -10
10°C
DHW time setting:
Select "SET DHW TIME" and press " " to entry. Display as follows: