20190951
4.7 F1Troubleshooting
Digitaldisplayoutput

Description
LowDCgeneratrixvoltage.
M‐ThermalSplitstopsrunning.
ErrorcodeisdisplayedonhydronicsystemmainPCBanduserinterface.
Possiblecauses
TheDCgeneratrixvoltageistoolow.
Procedure
F1

Powersupplyisabnormal.
Yes
Providenormalpower
No

LEDontheInverter
Modulesislighting
Yes
VoltageofPNis380V.
Yes
Checkthemainboard.
No

Theinputpowerof
invertermoduleis
abnormal
Yes
Themainboardis
damaged,changeit.

No

Theinvertmoduleis
damaged,changeit.
