EXV open angle for 2# indoor unit
EXV open angle for 3# indoor unit
EXV open angle for 4# indoor unit
Power supply of outdoor unit AD data
The indoor unit can communicate with outdoor unit well.
The last error or protection code
Ambient temp. of 1# indoor unit
Condenser pipe temp. of 1# indoor unit
Ambient temp. of 2# indoor unit
Condenser pipe temp. of 2# indoor unit
Ambient temp. of 3# indoor unit
Condenser pipe temp. of 3# indoor unit
Ambient temp. of 4# indoor unit
Condenser pipe temp. of 4# indoor unit
The following items from 6.4.1 to 6.4.6 are for the explanation of the point check functions.
8.4.1 Frequency of compressor:
Display Frequency of compressor (Hz)
30 30
-- Stand by
60 60
8.4.2 Running mode:
Display Corresponding mode
0 Off
1 Cooling mode
2 Heating mode
8.4.3 Capacity demand:
Cooling mode
Capacity 2000-2
500
2000-2
500
3000-3
800
4500-5
000
5000-5
500
5500-6
100
6100-7
000
7000-7
500
7500-8
000
>7500
Correspondi
ng Code
1 2 3 4 5 6 7 8 9 >=10
Heating mode
Capacity 2000-2
500
2000-2
500
3000-3
800
4500-5
000
5500-6
100
6100-7
000
6100-7
000
7000-7
500
7500-8
000
>8000
Correspondin
g Code
1 2 3 4 5 6 7 8 9-10 >=11
Note:
The capacity is just for reference.