EasyManua.ls Logo

Midea M4OC-36HRFN1-M - Page 105

Midea M4OC-36HRFN1-M
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Reactor
How to remove the reactor
1) Perform work of item 1,2
2) Unfasten the connector
between IPM and reactor.
3) Remove two screws of
cover of inductance, and
remove the cover of
inductance
4) Disconnect two pieces of
wires connected from the
cover of inductance.
5) Remove two screws of
reactor, and remove the
reactor.
6
The 4-way
valve
How to remove the 4-way valve
1) Perform work of item 1,2.
2) Extract refrigerant gas.
3) Remove the electrical parts
from item 3.
4) Remove fixing screw of the
coil, and remove the coil.
5) Detach the welded parts of
4-way valve and pipe.
7
The
expansion
valve
How to remove the expansion
valve
1) Perform work of item 1,2.
2) Remove the electrical parts
from item 3..
3) Remove the coils.
4) Detach the welded parts of
expansion valves and pipes.
Screws of
cover of
inductance
Screws of
reactor
Coil
Welded parts
Coils
Expansion
valves