43 Average value of T2 (Sum T2 value of all indoor units)/(number of indoor units in good
connection)
44 Outdoor unit fan motor state Off: 0, High speed:1, Med speed: 2, Low speed: 3, Breeze:4,
Super breeze: 5
45 The last error or protection code 00 means no malfunction and protection
46 F indoor unit capacity
47 F indoor unit capacity demand code
48 F indoor unit evaporator outlet temperature
(T
2B
F)
49 F indoor unit room temperature (T
1
F)
50 F indoor unit evaporator temperature (T
2
F)
51 EXV open angle for F indoor unit
8.3.2 Outdoor Unit Digital Display
A digital display is featured on the outdoor PCB.
The LED displays different codes in the following situations:
Standby: “- -.”
Compressor operation: the running frequency.
Defrosting mode: “dF” or alternative displays between running frequency and
“dF” (ach appears for 0.5s.)
Compressor pre-heating: “PH” or alternative displays between running frequency
and “PH” (each appears for 0.5s.)
Oil return process: “RO” or alternative displays between running
frequency and “RO” (each appears for 0.5s.)
Low ambient cooling mode: “LC” or alternative displays between running
frequency and “LC” (each appears for 0.5s.)
Forced cooling mode: the LED displays “FC” or alternative displays between running
frequency and
“FC” (each appears for 0.5s).
PFC module protection occurs three times within 15 minutes: “E6” or
alternates between displays of running frequency and “E6” (each appears for 0.5s.)
In protection or malfunction, the LED displays an error code or protection code.