8.4.2.8 P1 (High pressure protection) diagnosis and solution.
Error Code
P1
Malfunction conditions
If the sampling voltage is not 5V, the LED will display the
failure.
Potential causes
Wiring mistake
Faulty over load protector
System block
Faulty outdoor PCB
Trouble shooting: