EasyManua.ls Logo

Midea MCH2U-18PHH2

Midea MCH2U-18PHH2
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80
8.4.2.9 P2 (Low pressure protection) diagnosis and solution.
Error Code
P2
Malfunction conditions
If the sampling voltage is not 5V, the LED will display the
failure.
Potential causes
Wiring mistake
Faulty over load protector
System block
Faulty outdoor PCB
Trouble shooting:

Related product manuals