EasyManua.ls Logo

Midea MFAU-12FNXD0 - Error Codes

Midea MFAU-12FNXD0
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Error Codes
Number
Cause
The number
of flashes
per second
Timer
indicator
Error
Code
1
Indoor EEPROM (Electrically Erasable Programmable
Read-Only Memory) error
1 Off
E0
2 Indoor and outdoor unit communication malfunction 2 Off
E 1
3 Indoor fan speed malfunction 4 Off
E3
4 Indoor room temperature sensor error 5 Off
E4
5 Evaporator coil temperature sensor error 6 Off
E5
6 Refrigerant leak detection system malfunction 7 Off
EC
7 Water level alarm malfunction 8 Off
EE
8
Dual indoor unit (twin model only) communication
malfunction
9 Off
E8
9 Other twin model malfunction 10 Off
E9
10 Overload protection 1 On
F0
11 Outdoor temperature sensor error 2 On
F 1
12 Outdoor condenser pipe sensor error 3 On
F2
13 Discharge air temperature sensor error 4 On
F3
14
Outdoor EEPROM (Electrically Erasable
Programmable Read-Only Memory) error
5 On
F4
15 Outdoor fan speed (DC fan motor only) malfunction 6 On
F5
16 T2b sensor error 7 On
F6
17
18
19
20
Inverter module IPM protection 1 Flash
P0
21
High/Low voltage protection 2 Flash
P 1
22
Compressor top overheating protection 3 Flash
P2
23
Outdoor low temperature protection 4 Flash
P3
24
Compressor drive error 5 Flash
P4
Mode conflict 6 Flash
P5
Compressor low-pressure protection 7 Flash
P6
Outdoor IGBT sensor error 8 Flash
P7
Page 13