EasyManuals Logo

Midea MHA-V6W/D2N8-B User Manual

Midea MHA-V6W/D2N8-B
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
M thermal Split
106 202004
Midea M thermal Split
Service Manual
Procedure 4.25.4
bH
Power supply problem. After 5
minutes of power-
off interval,
power on again and observe
whether it can be recovered.
Yes
Increase the power voltage to the
required range.
No
PED
1
board broken.
Yes
Replace PED PCB and power on again.
No
IPM module broken.
Yes
Replace IPM module and power on again.
Notes:
1. PED is port CN22 on the hydronic box main PCB (labeled 11 in Figure 4-2.7: MHA-V12(14,16)W/D2RN8-B outdoor unit inverter module ).
Midea CAC
Confidential

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MHA-V6W/D2N8-B and is the answer not in the manual?

Midea MHA-V6W/D2N8-B Specifications

General IconGeneral
BrandMidea
ModelMHA-V6W/D2N8-B
CategoryAir Conditioner
LanguageEnglish

Related product manuals