NOTE: The minimum distance between the outdoor
unit and walls described in the installation guide does
not apply to airtight rooms. Be sure to keep the unit
unobstructed in at least two of the three directions (M,
N, P) (See Fig. 5.10)
Fig. 5.10
Drain Joint Installation
Before bolting the outdoor unit in place, you must install
the drain joint at the bottom of the unit. (See Fig. 5.11)
1. Fit the rubber seal on the end of the drain joint that
will connect to the outdoor unit.
2. Insert the drain joint into the hole in the base pan of
the unit.
3. Rotate the drain joint 90° until it clicks in place
facing the front of the unit.
4. Connect a drain hose extension (not included) to
the drain joint to redirect water from the unit during
heating mode.
NOTE: Make sure the water drains to a safe location
where it will not cause water damage or a slipping
hazard.
Seal
Drain joint
(A) (B)
Base pan hole of
outdoor unit
Seal
Fig. 5.11
Notes On Drilling Hole In Wall
You must drill a hole in the wall for the refrigerant piping,
and the signal cable that will connect the indoor and
outdoor units.
1. Determine the location of the wall hole based on the
location of the outdoor unit.
2.
NOTE: When drilling the wall hole, make sure
to avoid wires, plumbing, and other sensitive
components.
3. Place the protective wall cuff in the hole. This
protects the edges of the hole and will help seal it
when you finish the installation process.
Outdoor Unit
Installation
Using a 65-mm core drill, drill a hole in the wall.
Page 15
evoba
mc06
60cm
on right
30cm
on left
200cm
in front
30cm