Wiring Diagrams
Wiring Diagrams
Page 23
S
ROOM TEMPERATURE SENSOR
PIPE TEMPERATURE SENSOR
SWING MOTOR1
5
M
CN5
INDOOR UNIT
OUTDOOR UNIT
YELLOW
JX1
Y/G
WHI ET
RED
CN6_1
CN12_1
CN6_2
CN12_2
M
CN14
5(10)
SWING MOTOR2
OPTIONAL
MICRO SWITCH
PLASMA
2
CN43
CN44
OPTIONAL
IN FAN
M
5
CN4
N
CN11(CN1)
CN16
CN8
CN9
2
2
RY1
L-OUT
L-IN
P_1
W
2(N)
S
BLUE(BLACK)
ION
OPTIONAL
Y/G
HEATER
OPTIONAL
NOTE: If used as MONO unit, for the standby control needs, the cross section area of cable connected to W, 1(L)
must be sufficient for the maximum system current. The maximum system current is equal to the sum of indoor unit
and outdoor unit rated current. If used as MULTI unit, W on the terminal block does not need to be connected.
OPTIONAL
DISPLAY BOARD
CN10A
8(7)
(CN10)
Wire Controller
2
OPTIONAL
MULTI-FUCTION CONTROL BOX
OPTIONAL
1(L)
OPTIONAL
CN2(CN101)
CN3(CN301)
2
CN9
CN602
DISPLAY BOARD
CN1(OR CN201)
CN3(OR CN301)
CN2(OR CN101)
8
Wire Controller
WiFi Controller
4
4
4
8
5
5
5
OPTIONAL
WiFi Controller