EasyManua.ls Logo

Midea MOB2-12HN1-QC2 - Troubleshooting Guide; Indoor Unit Error Displays

Midea MOB2-12HN1-QC2
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
9. Troubleshooting
9.1 Indoor unit error display
For MSR1-21CRN1-QB8W, MSR1-24CRN1-QB8W models:
Operation
lamp
Timer
lamp
Auto lamp Failure
Over current protection occurs 4 times.
X X The T2 sensor is open circuit or short circuit
X X The T1 sensor is open circuit or short circuit
X EEPROM error
X X Indoor / outdoor units communication error
For MSR1-21HRN1-QB8W, MSR1-21HRN1-QB4W, MSR1-24HRN1-QB4W, MSR1-24HRN1-QB8W
models:
Operation
lamp
Timer
lamp
Defrosting
lamp
Auto
lamp
Failure
X Over current protection occurs 4 times.
X X X The T2 sensor is open circuit or short circuit
X X X The T1 sensor is open circuit or short circuit
X X X The T3 sensor is open circuit or short circuit
X X EEPROM error
X X X Indoor / outdoor units communication error
Olight Xoff flash

Related product manuals