63
19
Evaporator pipe temperature T2 of 1# indoor
unit
If the temperature is lower than 0 degree, the digital display
tube will show “0”.If the temperature is higher than 70
degree, the digital display tube will show “70”. If the indoor
unit is not connected, the digital display tube will show:
“――”
20
Evaporator pipe temperature T2 of 2# indoor
unit
21
Evaporator pipe temperature T2 of 3# indoor
unit
22
1# Indoor unit capacity demand code
Actual data*HP*10
If capacity demand code is higher than 99, the digital display
tube will show single digit and tens digit. (For example, the
digital display tube show “5.0”,it means the capacity demand
is 15. the digital display tube show “60”,it means the
capacity demand is 6.0). If the indoor unit is not connected,
the digital display tube will show: “――”
23
2# Indoor unit capacity demand code
24
3# Indoor unit capacity demand code
25
Room temperature T1 of 1# indoor unit
If the temperature is lower than 0 degree, the digital display
tube will show “0”.If the temperature is higher than 70
degree, the digital display tube will show “70”. If the indoor
unit is not connected, the digital display tube will show:
“――”
26
Room temperature T1 of 2# indoor unit
27
Average room temperature T1
28
Reason of stop
29
Evaporator pipe temperature T2B of 1# indoor
unit
If the temperature is lower than 0 degree, the digital display
tube will show “0”.If the temperature is higher than 70
degree, the digital display tube will show “70”. If the indoor
unit is not connected, the digital display tube will show:
“――”
30
Evaporator pipe temperature T2B of 2# indoor
unit