EasyManua.ls Logo

Midea MOX630U-55HFN8-RRD0WGA - Safety Caution

Midea MOX630U-55HFN8-RRD0WGA
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Page 39
1. Safety Caution
WARNING
Be sure to turn off all power supplies or disconnect all wires to avoid electric shock.
While checking indoor/outdoor PCB, please equip oneself with antistatic gloves or wrist
strap to avoid damage to the board.
WARNING
Electricity remains in capacitors even when the power supply is off.
Ensure the capacitors are fully discharged before troubleshooting.
Test the voltage between P and N on back of the main PCB with multimeter. If the voltage is lower than 36V, the
capacitors are fully discharged.
Note: This picture is for reference only. Actual appearance may vary.