Midea MOX630U-55HFN8-RRD0WGA - FL 09(Indoor and Outdoor Mismatch Malfunction Diagnosis and Solution); PC 0 L (Low Ambient Temperature Protection); PC 45 (Outdoor Unit IR Chip Drive Failure Diagnosis and Solution)

Midea MOX630U-55HFN8-RRD0WGA
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Page 79
8.18 PC 45 (Outdoor unit IR chip drive failure diagnosis and solution)
Description: When the IR chip detects its own parameter error, the LED displays the failure code when power on.
Recommended parts to prepare:
Inverter module PCB.
Troubleshooting and repair:
Power off,then restart the unit
2 minutes later.
Replace the inverter module
PCB.
Yes
8.19 PC 0L (Low ambient temperature protection)
Description: It is a protection function. When compressor is off, outdoor ambient temperature(T4) is lower than -35
o
C.
for 10s, the AC will stop and display the failure code.
When compressor is on, outdoor ambient temperature(T4) is lower than -40
o
C.for 10s, the AC will stop and display the
failure code.
When outdoor ambient temperature(T4) is no lower than -32
o
C.for 10s, the unit will exit protection.
8.20 FL 09(Indoor and outdoor mismatch malfunction diagnosis and solution)
Description: Indoor and outdoor units are mismatched, the LED displays this code. Please replace the matching indoor
or outdoor unit..

Table of Contents