Oasis On-off DM12-01.01.09en
46 Service manual
For 24k model:
TE7() TE8() TE9()
60 53 50
10.4.4 Auto-mode
This mode can be chosen with remote controller and the setting temperature can be changed between
17~30.
In auto mode, the machine will choose cooling, heating or fan-only mode according to T (T =T1-Ts).
T=T1-Ts Running mode
T2
Cooling
-3≤∆T2
Fan-only
T<-3
Heating
AC will run in auto mode in the below cases:
1 Pressing the forced auto button.
2 If AC is off, it will run in auto mode when the timer on function is active.
3 After setting the mode, AC will run in auto mode if the compressor keeps not running for 20
minutes.
10.4.5 Drying mode
10.4.5.1 The compressor is cycled running with 10 minutes on and then 5 minutes off. The indoor fan
will keep running at low speed.
10.4.5.2 In drying mode, if room temperature is lower than 10, the compressor will stop and not
resume until room temperature exceeds 13.
10.4.5.3 The evaporator anti-freezing protection is the same as that in cooling mode.
10.4.6 Forced operation function
Press the touch button continually, the AC will run as below sequence:
Forced auto Forced cooling Off
Forced cooling mode: