DM12-01.01.09en Oasis On-off
Service manual 43
The air conditioner will not detect whether it needs to run at defrosting mode until the compressor has
run for no less than 6.5 minutes.
Model DT1
MS11M-09HRN1 / MO11M-09HN1
7.5
MS11M-12HRN1 / MO11M-12HN1
MS11M-18HRN1 / MO11M-18HN1
6.0
Condition of ending defrosting:
If one of following conditions is satisfied, the AC will end the defrosting mode and turn into heating
mode:
A. The defrosting time has ended
B. The compressor current has reached or exceeded I
DEFROST
for 7 seconds
Model I
DEFROST
MS11M-09HRN1 / MO11M-09HN1
3.0
MS11M-12HRN1 / MO11M-12HN1
4.5
MS11M-18HRN1 / MO11M-18HN1
7.0