Oasis On-off DM12-01.01.09en
48 Service manual
timing is less than 7 hours, sleep function will be cancelled when reaching the setting time. If the timing
is more than 7 hours, the machine will not stop until reaches the setting time in sleep mode.
10.4.9 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart
module. In case of a sudden power failure, the module memorizes the setting conditions before the
power failure. The unit will resume the previous operation setting (not including swing function)
automatically after 3 minutes when power returns.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30 minutes
and turn to auto mode as 24℃ setting temp.
If AC is off before power off and AC is required to start up now, the compressor will have 1 minute
delay when power on. Other conditions, the compressor will have 3 minutes delay when restarts.
10.4.10 Follow me
1) If the indoor PCB receives the signal which results from pressing the FOLLOW ME button on
remote controller, the buzzer will emit a sound and this indicates the follow me function is initiated. But
when the indoor PCB receives signal which sent from remote controller every 3 minutes, the buzzer
will not respond. When the unit is running with follow me function, the PCB will control the unit
according to the temperature from follow me signal, and the temperature collection function of room
temperature sensor will be shielded, but the error detective function of room temperature sensor will
be still valid.
2) When the follow me function is available, the PCB will control the unit according to the room
temperature from the remote controller and the setting temperature.
3) The PCB will take action to the mode change information from remote controller signal, but it
will not affected by the setting temperature.
4) When the unit is running with follow me function, if the PCB doesn’t receive any signal from
remote controller for 7 minutes or pressing FOLLOW ME button again, the follow me function will be
turned off automatically, and the temperature collection function of room temperature sensor will be
available, the PCB will control the unit according to the room temperature detected from its own room
temperature sensor and setting temperature.
10.4.11 Self clean
For heat pump models which are provided with this function, after running in cooling or drying mode, if