11.2 Troubleshooting
For 9K and 12K :
Failure phenomenon
Operation
lamp
Timer
lamp
Indoor fan speed has been out of control for over 1 minute
X
Indoor room temp. or evaporator sensor is open circuit or short circuit
On
Over current protection of the compressor occurs 4 times X
EEROM error On
Indoor unit communication error
illumine simultaneous
Outdoor condenser temperature sensor is open circuit or short circuit
illumine alternately
r Extinguish
Flash at 5Hz
For 18K:
Failure phenomenon
Operation
lamp
Timer
lamp
Defrosting
lamp
Auto
lamp
Over current protection of the compressor occurs 4 times
Indoor room temp. sensor is open circuit or short circuit X X X
Temp. sensor on indoor evaporator is open circuit or short circuit X X X
Temp. sensor on outdoor condenser is open circuit or short circuit
(without for cooling only models)
X X X
Outdoor unit protects(outdoor temp sensor, phase order etc) X X
EEROM error X X
Indoor unit communication error X X X