35
9.1 Indoor Unit Error Display
Display LED STATUS
E0 EEPROM parameter error
E1 Indoor / outdoor units communication protection
E2 Zero-crossing signal error
E3 Indoor fan speed out of control
E5 Open or short circuit of outdoor temperature sensors
E6 Open or short circuit of indoor temperature sensors
E7 Outdoor fan speed out of control
E8 Reset error of Auto Clean filters
P0 IGBT over-strong current protection
P1 Over voltage or too low voltage protection
P2 Temperature protection of compressor top.
P4 Inverter compressor drive error
Note: E4 & P3: Reserved function