Troubleshooting
Electrical Control System 180
Inverter compressor drive protection
P4
5
Compressor low pressure protection
P6
7
Outdoor IGBT sensor is faulty
P7
8
O (on) X(off) (flash at 2Hz)
2.3 Outdoor Unit Malfunctions
For 16K:
Contents
LED1(Green)
LED2(Red)
Normal standby
On
Off
Normal operation
Off
On
DC voltage too high/too low protection or MCE malfunction
On
On
Compressor driven chip EEPROM malfunction
On
Flash
Compressor speed malfunction
Off
Flash
Zero speed protection or synchronous fault protection
Flash
On
IGBT strong current protection or IPM module protection
Flash
Off
Communication error between outdoor main chip and compressor driven chip
Flash
Flash
For 18~60K:
Display
Malfunction or Protection
E1
Communication malfunction between indoor and outdoor units
F0
Overcurrent protection
F1
Ambient temperature sensor (T4) malfunction
F2
Outdoor heat-exchanger temperature sensor (T3) malfunction
F3
Discharge temperature sensor (T5) malfunction
F4
Outdoor EEPROM malfunction
F5
Outdoor fan speed malfunction
P0
IPM module protection
P1
DC voltage too high/too low protection
P3
Ultra-low ambient temperature protection
P4
Compressor rotor position protection
J0
Evaporator high temperature protection
J1
Condenser high temperature protection
J2
High discharge temperature protection
J3
PFC module protection
J4
Communication error between outdoor main chip and compressor driven chip
J5
High pressure protection
J6
Low pressure protection
P7
IGBT sensor malfunction
J8
AC power input voltage protection
In low ambient cooling mode, the LED displaysLCor alternates between running frequency and LC(each
appears for 0.5s).