30
C17
5
Indoor unit
horizontal swing
setting
00: None
Common
Indoor Unit:
01
FAPU: 00
01: Available
C18
Display of
indoor unit to
receive the
remote control
signals
00: No
01
01: Yes
C19
Buzzer of the
indoor unit rings
00: No
01
01: Yes
C20
Follow Me in
wired controller
temperature
correction
Celsius:
-5.0~5.0°C
Fahrenheit:
-9.0~9.0°F
Celsius:
-3.0°C
Fahrenheit:
-6.0°F
Accuracy is 0.5°C/1°F.
C21
Set outdoor
ambient
temperature
value when
auxiliary
heater is on
Celsius:
-5~20°C
Fahrenheit:
23-68°F
Accuracy is 1°C/1°F.
C22
Mode switch
interval in Auto
mode
00/01/02/03 00
Parameter 00 01 02 03
Value
Represents
15 Min
30 Min 60 Min 90 Min
Remarks
Default
Value
Select
Parameters
Parameter
Content
Parameter
Code
Celsius:
15 °C
Fahrenheit:
59 °F