Example 1:
Reprogramming the drum reversing action
period (standard = 1 minute and
27 seconds) in the cotton programs.
A drum reversing action period can be se
-
lected from 20 seconds to 2 minutes.
Here a reversing time of 1 minute and
5 seconds is chosen.
^ Turn the program selector to program A /
A.
The following will alternate in the additional
display:
or
^
Press and release the "Start" button until
"I 05" appears in the additional display.
^ Turn the program selector to the "t
End"position to store the program change.
To exit programming:
^
Press the "s On/Off"button.
Enter any program changes to the "Repro
-
gramming possibilities" chart.
Reprogramming