EasyManua.ls Logo

Migatronic SIGMA2 300 Compact - Software Management; Software Update and Loading

Migatronic SIGMA2 300 Compact
150 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
SOFTWARE
In case of exchange of the control unit, software must
be reloaded, using an SD card.
Latest software can be downloaded under Product
software at www.migatronic.com/login. Save the
software on an SD card containing the folders and one
or more of the files shown below.
To order SD card, use item no. 12646000.
Software reading
Insert the SIGMA SD-card in the slide in the right
side of the machine.
Turn on the machine.
The display flashes shortly with six lines.
Wait until the set current is displayed.
Turn off the machine and remove the SD card
The machine is now ready for use.
If the SD-card contains software for other units e.g.:
10020115.cry RWF
10020113.cry RCI
These units will be updated if they are connected to
the CAN network.
Please note that this update will be longer in time, so
please do not turn off the machine until the standard
control panel will be displayed at SIGMA.
All machine user settings are deleted when
the file 106454xx.bin has been inserted.
Therefore, always remove the SD-card from the
machine after the software update. Thereby,
continuous software update is avoid each time
the machine is turned on.