Loading...
3-8
Set the distance compensation
13
After plotting is completed, the current correction
value is displayed.
14
Actually measure OFF lines of AR, AL and B.
Move the clamp lever to the rear side, remove the sheet and
measure.
15
Perform the operations in Steps 2 to 13.
As the sheet is not set, the correction entry screen is displayed without performing plotting.
16
If the measured value is different from the standard
value, change the correction value with .
17
Press the key to register the correction
value of AR direction.
You can register it by the key.
Moves to the standard length setting of AL direction.
18
In the same way as the Step 14, enter the correction
value of AL with .
19
Press the key to register the correction
value of AL direction.
You can register it by the key.
Moves to the standard length setting of B direction.
20
Change the correction value of B direction with
.
21
Press the key to register the correction
value of B direction.
When you press the key, the screen returns to step3.