Chapter 6 Maintenance
149
1
Use tweezers to peel off the end of the pen line rubber.
Wipe off any adhesive remaining in the platen slot with alcohol.
2
Attach the double-sided tape provided into the platen slot.
3
Peel off the backing paper from the double-sided tape.
4
Attach a new pen line rubber on top of the double-sided tape.
Make sure the pen line rubber is laid flat.