Cut Out Data with Registration Mark
3
Useful Function
Correct the light pointer position
If the plotter fails to recognize any registration mark properly, the possible cause is an error in the positional
relationship between the MARK sensor and the light pointer.
In this case, adjust the position of the light pointer.
1
Install a water-based ball-point pen in
the tool holder.
• When making an adjustment, use the pen
dedicated for the plotter to reduce the fudge
factor. Any pen color works for the adjustment.
You can order the dedicated pen from a sales
office of MIMAKI.
2
Confirm that the plotter is in the local
mode.
3
Press the key.
4
Select [MARK SENSOR] by pressing
the jog key or .
5
Press the key.
6
Select [POINTER OFS] by pressing the
jog key or .
7
Press the key.
• A 10 mm by 10 mm cross pattern will be plotted.
• The light pointer turns on and moves to the center of the cross pattern.