EasyManua.ls Logo

MIMAKI CG-60SR - Page 87

MIMAKI CG-60SR
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cut Out Data with Registration Mark
3-39
3
Useful Function
7
Enter the corrected value (mm) by
pressing the jog keys for the A
direction, or the for the B direc-
tion.
If misaligned by +0.2 mm, enter “-0.2”.
8
Press the key.
The plotter will return to the local mode after
registering the compensation value.
The setting values are kept in memory even when the power is turned off.
The sensor offset value selected by this operation is not initialized by SETUP RESET
operation.
A= - 0 . 2 B= - 0 . 2
CUT1 20 050 0 . 30
ENTER/HOLD