4.3.10 Adjusting the Location of Mark Sensor
Function
Adjust the distance between the mark sensor (photo sensor) and the platen to the specified value.
Procedure
1. From the back side of the printer, loosen the screws (x2) that
hold the T sensor BKT.
Set the pressure of all the clamps to Middle, and make the adjustment on the right station side.
This adjustment is to be made mechanically without using any [#ADJUST] item. After completion of
this adjustment, however, make the adjustments of [PHOTO SENSOR] among the [#ADJUST] items.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
2.8 mm
+0.2/-0.0
Mark sensor
When no sheet is set: the plotter waits for input of a
compensation value without plotting.