© 2014 MIMAKI ENGINEERING CO.,LTD. 5.1.6 P.1
1
2
3
4
5
6
7
8
R.1.0
5.1.6 CHECK TEMP.
Outline
Temperature check of each part that monitors temperature is available.
Content
The temperature in the table below is displayed.
Display Content
IO HEATSINK 1
COM IO PCB Heat sink 1
IO HEATSINK 2
COM IO PCB Heat sink 2
SL2H THERMISTOR Temperature of SL2H PCB
HEAD1 Head temperature of head 1
HEAD2 Head temperature of head 2 (Not displayed for 150 series)
ROOM AIR
Room temperature