© 2014 MIMAKI ENGINEERING CO.,LTD. 6.2.4 P.1
1
2
3
4
5
6
7
8
6.2.4 Selective Path Pump Assy
Work procedures
1. Remove the Under cover R, Cover R and Cover R2.
2. Remove the tubes from the Cap1 and Cap2, remove the Fit-
ting connected to the pump tube.
3. Remove the pump tube connected to the waste ink tank.
4. Remove the connector.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
Be sure to wear protective glasses and working gloves during the operation.
Ink may get into your eyes depending on the working condition, or hand skin may get rough if you touch
the ink.
Cap1 and 2 side
Take care not to pollute the surroundings with waste
ink or washing liquid.
Connector
Remove tube
Take care not to pollute the surroundings with waste
ink or washing liquid.
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Ink-related Parts > Selective Path Pump Assy
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0
Rev.

Table of Contents