© 2014 MIMAKI ENGINEERING CO.,LTD. 6.3.8 P.1
1
2
3
4
5
6
7
8
6.3.8 Take-up Motor
Work procedures
1. Remove the Take-up cover.
2. Disconnect all connectors. (for sensor x2, for motor x1)
3. Remove the Take-up motor together with the Take-up motor
BKT (screw x3).
4. Remove the screws (x4) and then remove the Take-up motor.
5. Reverse the disassembly procedure for reassembly.
Take-up motor
Take-up motor BKT1
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Drive System > Take-up Motor
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0