© 2014 MIMAKI ENGINEERING CO.,LTD. 6.4.13 P.1
1
2
3
4
5
6
7
8
6.4.13 CG common slider PCB Assy.
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the C head cover.
3. Disconnect the all connectors on the PCB.
4. Remove the CG common slider PCB Assy. (Screw x2)
5. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF.
It is very dangerous if sleep mode functions mistakenly during the operation.
CG common slider PCB Assy
CG common slider PCB Assy.
FFC
Connection sensor dog
Connection
sensor
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > CG common slider PCB Assy.
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0