MAINTENANCE MANUAL > Workflow > Ink Related Parts > Replacement of the Selective path Assy.
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver.
1.00
Remark
1.0
Rev.
3.1.5 Replacement of the Selective path Assy.
List of replacement procedures
Item Work operation Description Ref.
Covers
1.
Removal of covers, etc. Remove the Under cover R, cover R and cover R2. 6.1.1
Pass select
pump Assy.
2.
Removal of the Selective path
Assy.
Remove the Selective path Assy. 6.3.6
3.
Mounting of the Selective path
Assy.
Mount the Selective path Assy.
Covers
4.
Mounting of the covers. Mount the covers that have been removed. 6.1.1
Be sure to wear protective glasses and working gloves during the operation.
Ink may get into your eyes depending on the working condition, or hand skin may get rough if you touch
the ink.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.