3.4.1 Replacement of the Pen Assy and LED Pointer
List of replacement procedures
Item Work operation Description Ref.
Covers
1.
Removal of covers, etc. Remove the C head cover. 6.1.1
Pen assy,
LED pointer
2.
Removal of the pen assy. Remove the pen assy. 6.6.2
3.
Removal of the LED pointer. Remove the LED pointer from the pen assy.
4.
Mounting of the LED pointer. Mount the LED pointer to the pen assy.
In installation, pay attention to harness treatment.
5.
Mounting of the pen assy. Mount the pen assy.
Adjustment
6.
Adjustment of the pen stroke Adjust the pen stroke at 5 ±0.2 mm.
*Pinch roller pressure is “middle” for all pinch rollers.
7.
Adjustment of pen pressure Adjust the [PEN PRESSURE]. 4.2.21
9.
Adjustment of the photo sensor Adjust the [#ADJUST] - [#PHOTO SENSOR]. 4.2.23
Check
10.
Check each performance Check the [CUT PATTERN] and cutting position. Carry out
“print & cut” online to confirm no misalignment is found.
Covers
11.
Mounting of the covers Mount the covers that have been removed. 6.1.1
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions