Chapter 6 Maintenance
152
7
Mount a new wiper.
Lug
8
Once replacement is complete, close the cover, then press the [ENTER] key.
The wiper usage count is reset.
9
Once replacement is complete, close the cover, then press the [ENTER] key.
Cap Replacement
If ejection failures (e.g., nozzle clogging or deflection) remain unresolved even after cleaning, replace with a
new cap.
Be sure to replace the cap if you observe any scratches or other damage on the rim.
We recommend replacing the cap every six to twelve months.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
The Maintenance menu is displayed.
2
Select [Station Maint.] > [Replace Cap], then press the [ENTER] key.
The carriage moves over the platen.
3
Open the maintenance cover (right side).