Remove the cap.
Squeeze the lugs on either side of the cap and pull off.
5
Apply maintenance liquid.
Use a syringe to apply two or three drops of maintenance liquid to the hole at the front.
6
Mount a new cap.
Position with the slot at the front and push in until it clicks.
7
Once replacement is complete, close the cover, then press the [ENTER] key.
Replacing the Absorber Around the Station
If the cap absorber or maintenance liquid absorber is very dirty or if ink drips on to the media, replace with a
new cap absorber.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.