EasyManua.ls Logo

MIMAKI CJV200-160 - Page 172

MIMAKI CJV200-160
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Troubleshooting
172
4
Select [TP Offset], then press the [ENTER] key.
The register marks are detected, and a correction pattern is cut. Detach the cut part of the pattern
and check the adjustment values.
+-
-+
5
Input the numerical value of the position with the lowest vertical misalignment.
In the illustration below, the value is "-4", so enter "-0.4 mm".
-2 -5-4-3 -6
Enlarged X
6
Input the numerical value of the position with the lowest horizontal misalignment.
In the illustration below, the value is "2", so enter "0.2 mm".
4 123 0
Enlarged Y

Table of Contents