3-42
When using 600 cc cartridge for the first time
When the 600 cc cartridge is set in the slot of the ink station, the weight registration function of the eco case
automatically starts.
1
Measure the weight of the eco case.
• Measure the weight of the eco case only in advance.
• If the 600 cc ink pack is in the eco case, remove the 600 cc ink pack and then perform measurement.
2
Set the 600 cc cartridge in the ink station.
• Mount the 600 cc ink pack and the ink chip on the eco case, and set
it to the ink slot.
• The input screen for the weight of the eco case will be displayed.
3
Pressing the keys input the
weight of the eco case.
• Press the keys to move to another digit.
• Press the keys to input the weight.
4
Press the key.
• For setting 600 cc cartridges in multiple slots, repeat the procedures in Step 2 and 3.
• After all registration is completed, the device will return to the status before the weight registration function
was initiated.
CART.Slot ..3.....
case we i ght = 30
0 g
CART.Slot ..3.....
case we i ght = 35
5 g