6-17
Maintaining the Capping Station
6 6
Maintenance
Executes the NOZZLE PROTECT function automatically
You can set the status to enter the nozzle protection automatically (auto-execute function of NOZZLE PROTECT)
in case the device is not used for a certain amount of time.
In the nozzle protection status, NOZZLE PROTECT can be automatically executed regularly.
To use the auto-execute function of NOZZLE PROTECT, set the following items.
• On Time : Time from the stop of the device to the start of the nozzle protection status.
• Interval : Execution interval of NOZZLE PROTECT in the nozzle protection status.
1
Press the key in LOCAL to select the
printing mode.
2
Select [AutoNZL.PROTECT] of the maintenance menu.
(1) Press the key.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [AutoNZL.PROTECT] .
3
Press the key.
4
Press to select [ON Time].
• The machine not being used means that it is in the standby status or the status that the power supply
switch under the operation panel is OFF (the sleep status).
• The followings are the examples (three patterns) if you set the time length until the NOZZLE PROTECT
function is executed to “16h”.
In the nozzle protection status *2
In use On standby *1
Executing NOZZLE PROTECT
In use In sleep status *1
In use On standby *1
Power switch OFF
In sleep status *1
Power switch OFF
*1 : If the time length set in P.4-31 “Setting Routine operations” and P.4-28 “Preventing nozzle clogging
while power-off” has passed, maintenance operation is executed automatically.
*2 : In the nozzle protection status, a maintenance function set at P.4-28 “Preventing nozzle clogging while
power-off” does not work.
After entering the nozzle protection status, this machine automatically performs NOZZLE PROTECT
regularly.
Executing NOZZLE PROTECT
Executing NOZZLE PROTECT
In the nozzle protection status *2
In the nozzle protection status *2
<LOCAL . 1> [ #01 ]
WIDTH:****mm
Au t oNZL . PROTECT
ON T i me < e n t >
Au t oNZL . PROTECT
ON T i me < e n t >