6-17
Maintaining the Capping Station
6 6
Maintenance
Executes the NOZZLE PROTECT function automatically
You can set the status to enter the nozzle protection automatically (auto-execute function of NOZZLE PROTECT)
in case the device is not used for a certain amount of time.
In the nozzle protection status, NOZZLE PROTECT can be automatically executed regularly.
To use the auto-execute function of NOZZLE PROTECT, set the following items.
On Time : Time from the stop of the device to the start of the nozzle protection status.
Interval : Execution interval of NOZZLE PROTECT in the nozzle protection status.
1
Press the key in LOCAL to select the
printing mode.
2
Select [AutoNZL.PROTECT] of the maintenance menu.
(1) Press the key.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [AutoNZL.PROTECT] .
3
Press the key.
4
Press to select [ON Time].
The machine not being used means that it is in the standby status or the status that the power supply
switch under the operation panel is OFF (the sleep status).
The followings are the examples (three patterns) if you set the time length until the NOZZLE PROTECT
function is executed to “16h”.
In the nozzle protection status *2
In use On standby *1
Executing NOZZLE PROTECT
In use In sleep status *1
In use On standby *1
Power switch OFF
In sleep status *1
Power switch OFF
*1 : If the time length set in P.4-31 “Setting Routine operations” and P.4-28 “Preventing nozzle clogging
while power-off” has passed, maintenance operation is executed automatically.
*2 : In the nozzle protection status, a maintenance function set at P.4-28 “Preventing nozzle clogging while
power-off” does not work.
After entering the nozzle protection status, this machine automatically performs NOZZLE PROTECT
regularly.
Executing NOZZLE PROTECT
Executing NOZZLE PROTECT
In the nozzle protection status *2
In the nozzle protection status *2
<LOCAL . 1> [ #01 ]
WIDTH:****mm
Au t oNZL . PROTECT
ON T i me < e n t >
Au t oNZL . PROTECT
ON T i me < e n t >