© 2014 MIMAKI ENGINEERING CO.,LTD. 7.4 P.12R.1.0
1
2
3
4
5
6
7
INSTALLATION GUIDE > Outputting Plots > Dot Position Adjustment (Service mode)
Model
CJV300
Issue
2014.09.01
Revised F/W ver.
1.30
Remark
1.0
7.4 Dot Position Adjustment (Service mode)
Outline
Draw the built-in patterns, and compensate the parameter so that the drop positions of other heads are on the same
line as the drop position of reference head (Head 1A) in the Y-direction. To each of the discharged waveforms,
execute [SiDir], [ReDir] and [BiDir] in each resolution. Perform adjustment in accordance with the following chart.
(
O
: Implement this without fail.,
:Implement this as necessary.,
X
:Not needed.)
WF4(Large droplet waveform)
*1: The adjustment value for WF4/720dpi Hi is reflected in the WF4/360dpi Std single and reverse direction adjustment val-
ues (excluding bidirectional).
WF3(Small droplet waveform)
*2: The adjustment value for WF3/720dpi Std is reflected in the WF3/1440dpi Hi single and reverse direction adjustment val-
ues (excluding bidirectional).
Work Procedures
7. Display [#ADJUST] -> [PRINT ADJUST].
8. Select the waveform.
[]/[] : Switches
[ENTER] : Confirms (Next)
9. Select the Y-resolution and scanning speed.
[]/[] : Y-resolution & Scanning speed change
[ENTER] : Confirms (Next)
Y-reso lutio n
360 540 720 1440
BiDir SiDir ReDir BiDir SiDir ReDir BiDir SiDir ReDir BiDir
Std
O
*1
XXXXXX
Hi
X O O O O OXXXX
Y-reso lutio n
360 540 720 1440
BiDir SiDir ReDir BiDir SiDir ReDir BiDir SiDir ReDir BiDir
Std
O
OO
Hi
X O O O O O O
X
*2
X
*2
O
FUNCTION
#ADJUST [ENT]
#ADJUST
PRINT ADJUST [ENT]
#PRINT ADJUST
:360Std
360Std - 720Hi