4-10
4
Press to select ON, and then
press the key.
The correction value registered in AR (right side
of front-back direction), AL (left side of front-back
direction) and B (right-left direction) of No.1 are
displayed.
5
Press to select the distance
correction number to register, and then
press the key.
The standard length (mm) that was
corrected previous time is displayed.
If you do not perform distance correction at
all, the minimum standard length is
displayed.
When you change the length unit (mm/
inch) from you corrected previous time, the
under screen appears.
6
Press to change the standard
length of A direction (front-back direction),
and then press the key.
The standard length of A direction becomes
standard length of AR (right side of front-back
direction) and AL (left side of front-back direction).
When you change the standard length, the
distance correction value (AR, AL) corrected
previous time is cleared.
Moves to the standard length setting of B
direction.
7
Press to change the standard
length of B direction (right-left direction),
and then press the key.
When you change the standard length, the
distance correction value (B) corrected previous
time is cleared.
8
Press to specify the plotting
position of the distance correction
adjusting pattern, and then press the
key.
Offset all line segments (AR, AL, B) in the sheet.
Plot the adjusting pattern.
If a paper is not set, or, the paper size is too small
and the standard length cannot be plotted,
plotting is not performed. In such a case, when
you press the [ENTER] key, you can enter the
correction value without plotting.
9
After printing is completed, the current
correction value is displayed.
10
Actually measure OFF lines of AR, AL and B.
Move the clamp lever to the rear side, remove the
sheet and measure.
11
Perform the operations in Steps 2 to 9.
As the sheet is not set, the correction entry screen
is displayed without performing printing.
12
If the measured value is different from the
standard value, change the correction
value with .
13
Press the key to register the
correction value of AR direction.
You can register it by [>} key.
Moves to the standard length setting of AL
direction.
14
In the same way as the Step 10, enter the
correction value of AL with .
15
Press the key to register the
correction value of AL direction.
You can register it by [>} key.
Moves to the standard length setting of B
direction.
16
Change the correction value of B direction
with , and the press the
key.
Register the correction value of B direction.

Table of Contents