EasyManua.ls Logo

MIMAKI CJV300-130 - Division Cut Settings

MIMAKI CJV300-130
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-12
3
Press , and then press the
key.
“DIVISION CUT” will be selected.
4
Press to select “Y”, and then
press the key.
If you select “OFF”, setting for division cutting will
not be carried out. Proceed to step 9.
5
Press the key.
“FRAME CUT” will be selected.
6
Press to select a set value, and
then press the key.
Set value : ON, OFF
Select “ON” for the frame cut.
7
Press , and then press the
key.
“MARK CUT” will be selected.
8
Press to select a set value, and
then press the key.
Set value : ON, OFF
Select “ON” for the mark cut.
9
Press the key several times to
end the setting.
Set the X direction (feeding direction)
DIVISION CUT
If the data size of the feeding direction exceeds the
division length and cross cut length, the machine cuts it at
that position by dividing it.
If the cross cut length is set, the machine cuts by
overlapping it by the set value.
1
Press the
(MENU)
(>>)
key in LOCAL.
Cuttibg MENU will be displayed.
2
Press
(>>)
and then press the
key.
“SETUP SUB MENU” will be selected.
3
Press , and then press the
key.
“DIVISION CUT” will be selected.
4
Press to select “X”, and then
press the key.
If you select “OFF”, setting for division cutting will
not be carried out. Proceed to step 10.
5
Press the key.
“DIV. LENG” will be selected.
6
Press to select a set value, and
then press the key.
Set value : 50cm to 500 cm (in increments of
50cm)
When it exceeds the set value, the machine cuts it
at that position by dividing it.
7
Press , and then press the
key.
“CROSS CUT” will be selected.
8
Press to select a set value, and
then press the key.
Set value : 0mm to 50mm (in increments of 1mm)
The machine cuts by overlapping it by the set
value.
9
Press the key several times to
end the setting.
Reset the setting for DIVISION CUT
1
Press the
(MENU)
(>>)
key in LOCAL.
Cuttibg MENU will be displayed.
2
Press
(>>)
and then press the
key.
“SETUP SUB MENU” will be selected.
3
Press , and then press the
key.
“DIVISION CUT” will be selected.
4
Press the key.
“Setting” will be selected.
5
Press to select “OFF”, and then
press the key.
6
Press the key several times to
end the setting.
The setting values are kept in memory even when
the power is turned off.
During execution of division cutting, the plotter
ignores any other data sent from the host
computer.
In any of the following cases, the plotter cannot
perform division cutting.
The data size is larger than the receiver buffer
capacity.
An origin change command is contained in the
cutting data.
A two-point compensation value has been set.
The registration mark detection is being
performed.
The plotter cuts the test data stored in it.

Table of Contents

Other manuals for MIMAKI CJV300-130

Related product manuals