EasyManua.ls Logo

MIMAKI CJV330-160 - Ink Discharge Channel Cleaning

MIMAKI CJV330-160
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Maintenance
165
4
Clean the DAS sensor.
Wipe clean using cotton swabs or a soft cloth.
For heavy soiling, wipe using a soft cloth soaked in dilute detergent and thoroughly wrung
out.
5
Once cleaning is complete, close the cover, then press the [ENTER] key.
Ink Discharge Channel Cleaning
Clean the ink discharge channel regularly to prevent clogging of the ink discharge channel below the cap.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
The Maintenance menu is displayed.
2
Select [Station Maint.] > [Disway Wash], then press the [ENTER] key.
The cap is filled with maintenance liquid.
Close the cover. The cap cannot be filled with maintenance liquid while the cover is open.
This is also true if the maintenance liquid cartridge is empty.
3
Open the maintenance cover on the right side.
Check to confirm that the cap is filled with maintenance liquid.
If not, use a syringe to draw up some maintenance liquid and fill until it almost overflows
from the cap.
4
Close the maintenance cover, then press the [ENTER] key.
Pump tube (ink discharge channel below the cap) washing starts.
7

Table of Contents