Chapter 7 Maintenance
179
8
Wipe off maintenance liquid around the slider block.
9
Mount a new maintenance liquid absorber.
• Insert the maintenance liquid absorption into the protrusion firmly.
10
Check for floating or warped absorber.
11
Once replacement is complete, close the cover, then press the [ENTER] key.
If the plate is made of metal
Replace only the cap absorber.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station Maint.] > [Carriage Out] > [Move To Platen Right End], then press the [ENTER]
key.
• The carriage moves over the platen.
3
Open the maintenance cover on the right side.
4
Remove the cap absorber.
Cap absorber Plate (metal)
• Avoid ink dripping when removing the cap absorber.
7