Troubleshooting
5-10
5
Press the key.
Sensor adjustment starts.
6
Rotate the adjustment screw of the throttle valve to
adjust the pressure so that it becomes the proper
value.
Proper value of negative pressure: -5.40kPa
Proper value of positive pressure: 15.00kPa
As the negative pressure changes between ±0.1 and 0.2kPa, adjust so that the intermediate value may
become the target pressure.
Adjust the throttle valve in order of “negative pressure” “positive pressure” “negative pressure”.
7
Press the key.
The error is released and the negative pressure control starts.
When an error occurs even after you adjusted the pressure, contact your local distributor to call for
service.